General Specifications
- Manufacturer Integrated Power Designs
- Form Factor Open Frame
- Power 185 Watts
- Input 36 - 72 VDC
- Outputs Single, Dual, Triple or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- DC4-185-4001 3.3V, 5V, 12V, -12V
- DC4-185-4002 5V, 3.3V, 12V, -12V
- DC4-185-4003 5V, 3.3V, 15V, -15V
- DC4-185-4004 5V, -5V, 12V, -12V
- DC4-185-4005 5V, -5V, 15V, -15V
- DC4-185-4006 5V, 24V, 12V, -12V
- DC4-185-4007 5V, 24V, 15V, -15V
- DC4-185-3001 5V, 12V, -12V
- DC4-185-3002 5V, 15V, -15V
- DC4-185-2001 3.3V, 5V,
- DC4-185-2002 5V, 12V,
- DC4-185-2003 5V, 24V
- DC4-185-2004 12V, -12V
- DC4-185-2005 15V, -15V
- DC4-185-1001 2.5V
- DC4-185-1002 3.3V
- DC4-185-1003 5V
- DC4-185-1004 12V
- DC4-185-1005 15V
- DC4-185-1006 24V
- DC4-185-1007 28V
- DC4-185-1008 48V
Mechanical
- Dimensions 4.2 x 7 x 1.5 inches
- Operating Temperature 0°C + 70°C
- Humidity 95% RH
- MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
- Cooling Method Convection Cooled or 300 LFM Forced Air
-
Agency Approvals
UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
with updates 1 and 2
TUV: EN 60950-1:2001, EN 60601-1/A2:1995
IEC: CB Report per IEC 60950-1(2001),CB Report per IEC 60601-1(1988)
Output
-
Voltage Accuracy
Output 1: ±0.5%
Output 2,3,4: ±5% - Line Regulation 0.50%
-
Load Regulation
Output 1: 0.5%
Output 2: 5%
(4001,4,5, 2001):10%
(4002,3): 15%
Output 3: 5%
Output 4: 5% - Minimum Load 10%
-
Protections
Over voltage: Output 1: 110%-150%
Over power: 110%-160%, cycle on/off, auto recovery