General Specifications
- Manufacturer Integrated Power Designs
- Form Factor Open Frame
- Power 70 Watts
- Input 85-264 VAC
- Outputs Single, dual, Triple, or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- REL-70-4001 3.3V, 5V, 12V, -12V
- REL-70-4002 5V, 3.3V, 12V, -12V
- REL-70-4003 5V, 3.3V, 15V, -15V
- REL-70-4004 5V, -5V, 12V, -12V
- REL-70-4005 5V, -5V, 15V, -15V
- REL-70-4006 5V, 24V, 12V, -12V
- REL-70-4007 5V, 24V, 15V, -15V
- REL-70-4009 6.7V, 5V, 15V, -15V
- REL-70-3001 5V, 12V, -12V
- REL-70-3002 5V, 15V, -15V
- REL-70-3003 5.1V, 7.5V, -7.5V
- REL-70-3004 3.3V, 7V, 12V
- REL-70-2001 3.3V, 5V
- REL-70-2002 5V, 12V
- REL-70-2003 5V, 24V
- REL-70-2004 12V, -12V
- REL-70-2005 15V, -15V
- REL-70-2006 5.5V, -5.5V
- REL-70-1001 2.5
- REL-70-1002 3.3V
- REL-70-1003 5V
- REL-70-1004 12V
- REL-70-1005 15V
- REL-70-1006 24V
- REL-70-1007 28V
- REL-70-1008 48V
Mechanical
- Dimensions 2.5 x 4.5 x 1.2 inches
- Operating Temperature 0°C- +70°C
- MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
- Cooling Method Free air convection
-
Agency Approvals
General: Protection Class- 1, Over voltage catagory- II, Pollution Degree- 2
UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No. 601-1-M90 with updates 1and 2
TUV: EN 60950-1:2001, EN 60601-1/A2:1995
IEC: CB report per IEC
Output
-
Voltage Accuracy
Output 1: ±0.5%
Output 2,3,4: ±5% - Line Regulation 0.50%
-
Load Regulation
Output 1: 0.5%
Output 2: 5%
(4001-5, 2001): 8%
Output 3: 5%
Output 4: 5% - Minimum Load 10%
-
Protections
Output Over Voltage Protection: Output 1- 110%-150%
Output Over power protection: 110%-160%, cycle on/off, auto recovery